Medikro® Pro
PC-based laboratory spirometer
- All-in-one Laboratory Spirometer
- Embedded Ambient Condition Measurement
- Networking & Connectivity
- 3D Child Incentive
M915
Medikro® Pro represents the state of the art performance in PC-based spirometry. It is an accurate and precise diagnostic spirometer with embedded ambient condition measuring sensors for automatic real-time BTPS correction.
Pro takes advantage of easy to use Medikro® Spirometry Software (MSS). The system provides general practitioners the assurance of reliable results with an intuitive navigation, adjustable interpretation options and clear visualization of results. Medikro® Pro utilizes familiar disposable Medikro® SpiroSafe flow transducers. M9293 Bacterial & Viral Filters protects the operators of spirometry tests, while the Medikro® SpiroSafe flow transducers protect the patients from cross contamination. Both products are single use, and thereby eliminate the need for disinfection and sterilisation, facilitating maximum patient throughput.
Pro Highlights

Freddy the Frog incentive
Medikro’s Freddy the Frog is the only 3D incentive animation in the world. Freddy captures the attention of the children and encourages maximum performance. This improves the quality of spirometry results.

Cost-efficient
The combination of hardware and software features and the use of SpiroSafe disposables increases patient throughput and makes the system cost-efficient.

Patient safety
Disposable SpiroSafe flow transducers provide security in infection control. No exhaled air gets into the pressure tube or the device. This prevents patient-to-patient cross-contamination and protects the spirometer.

VCT technology
Vibration Control Tubing (VCT) cancels the signal noise caused by patient and tube movement. This stabilizes the signal and improves overall spirometry quality.

Automated realtime BTPS correction
The temperature, pressure and humidity sensors track environmental conditions automatically and enable true realtime BTPS correction.

Optional Bronchial Provocation
Use readymade bronchial provocation protocols, create them from the existing protocols or generate completely new ones.

Interpretation of Results
Adjustable interpretation options: Ventilation, Bronchodilatation, Spirometry findings, etc.

Trending
Monitors treatment effects, documenting potential need for treatment modifications and changes in lung function.

PDF export
Print final reports in PDF or as image, our software will do it for you automatically.

Medikro® Warranty & Safeguard
A service package which provides security and other benefits for all Medikro end-users.

XML/GDT Interface
XML/GDT transfer of session results into hospital information system (HIS/KIS/EPR).

Choice of Parameters
Free choice from over 100 parameters; various parameters can be chosen for an onscreen view and for the final report.

Quality Control
Real-time duration and flow indicator support quality control, providing a quick assessment tool for operators.

PRE/POST
Assessment of patient’s response to bronchodilatator is facilitated by pre- and post- function to support diagnosis.

Numeric and Graphic
Results are presented in numeric and graphic form, further support for diagnosis by ventilation function interpretation and spirometry finding field.
More features
Show all features
/Hardware Components
Automatic ambient unit | ![]() |
Spirometer | ![]() |
Spirometry Measurements
TV | ![]() |
MVV | ![]() |
SVC | ![]() |
FIVC | ![]() |
FVC + FIVC | ![]() |
FVC | ![]() |
Software Features
Bronchial Provocation | ![]() |
3D incentive Freddy the Frog | ![]() |
Interpretation | ![]() |
Automatic PDF/image export | ![]() |
Pre & post phase measurements | ![]() |
Measured parameters/variables | 102 |
Fully scalable software | ![]() |
Results and Databases
Automatic classification of bronchodilatation test | ![]() |
MS Access or any other ODBC and SQL capable database | ![]() |
XML based import and export functions | ![]() |
Final report | extended |
Reference sets | 32 |
Patient trend reports | ![]() |
Criteria of the best results: according to ATS and ERS recommendations | ![]() |
Histogram | ![]() |
Remote Use
Database access via the local area network (LAN) | ![]() |
Final report and signal data transfer via e-mail | ![]() |
Calibration
Calibration with the standard 3000 ml pulmonary calibration syringe, user defined volumes are allowed | ![]() |
Calibration results are recorded and stored in the calibration log file | ![]() |
Measurement Details
Meets the ATS/ERS standards | ![]() |
Maximum number of measurements | 8 measurements per phase |
Collection of the entire signal data, collection rate: 500 Hz | ![]() |
Maximum duration of one measurement | 60 s |
Determination of 0-time in FVC by back extrapolation | ![]() |
Metric and U.S. units | ![]() |
Variables
TV | ![]() |
FR | ![]() |
MV | ![]() |
MVV | ![]() |
MVVFR | ![]() |
MVVT | ![]() |
MVVDIFF | ![]() |
IRV | ![]() |
IC | ![]() |
EC | ![]() |
FVC | ![]() |
FEV0.25 | ![]() |
FEV0.5 | ![]() |
FEV0.75 | ![]() |
FEV1 | ![]() |
FEV2 | ![]() |
FEV3 | ![]() |
FEV4 | ![]() |
FEV5 | ![]() |
FEV6 | ![]() |
FVC%(VC) | ![]() |
FVC/FEF25-75 | ![]() |
FEV0.25%(VC) | ![]() |
FEV0.25%(FVC) | ![]() |
FEV0.25%(FEV6) | ![]() |
FEV0.5%(VC) | ![]() |
FEV0.5%(FVC) | ![]() |
FEV0.5%(FEV6) | ![]() |
FEV0.75%(VC) | ![]() |
FEV0.75%(FVC) | ![]() |
FEV0.75%(FEV6) | ![]() |
FEV1%(VC) | ![]() |
FEV1%(FVC) | ![]() |
FEV1%(FEV6) | ![]() |
FEV1%(FIV1) | ![]() |
FEV1/PEF | ![]() |
FEV2%(VC) | ![]() |
FEV2%(FVC) | ![]() |
FEV2%(FEV6) | ![]() |
FEV3%(VC) | ![]() |
FEV3%(FVC) | ![]() |
FEV3%(FEV6) | ![]() |
FEV4%(VC) | ![]() |
FEV4%(FVC) | ![]() |
FEV4%(FEV6) | ![]() |
FEV5%(VC) | ![]() |
FEV5%(FVC) | ![]() |
FEV5%(FEV6) | ![]() |
PEF | ![]() |
PEF%(PIF) | ![]() |
RT10-90 | ![]() |
DT90 | ![]() |
DT95 | ![]() |
PEFT | ![]() |
FEF25 | ![]() |
FEF50 | ![]() |
FEF75 | ![]() |
FEF25-75% | ![]() |
FEF70%(FIF50) | ![]() |
FEF25-75/VC | ![]() |
FEF25-75/FVC | ![]() |
METT | ![]() |
AEFV | ![]() |
FET | ![]() |
EV | ![]() |
EV%(FVC) | ![]() |
LAGE | ![]() |
FIVC | ![]() |
FIV0.5 | ![]() |
FIV1 | ![]() |
FIV6 | ![]() |
FIV0.5%(VC) | ![]() |
FIV0.5%(FIVC) | ![]() |
FIV0.5%(FIV6) | ![]() |
FIV1%(VC) | ![]() |
FIV1%(FIVC) | ![]() |
FIV1%(FIV6) | ![]() |
FIV1%(FEV1) | ![]() |
PIF | ![]() |
PIF%(PEF) | ![]() |
FIF25 | ![]() |
FIF50 | ![]() |
FIF75 | ![]() |
FIF25-75% | ![]() |
FIF70%(FEF50) | ![]() |
MITT | ![]() |
AIFV | ![]() |
FIT | ![]() |
IEV | ![]() |
IEV%(FIVC) | ![]() |
TIME | ![]() |
VC | ![]() |
VC%(FVC) | ![]() |
VC/FEF25-75 | ![]() |
VCDIFF | ![]() |
FVCDIFF | ![]() |
FEV1DIFF | ![]() |
PEFDIFF | ![]() |
SpiroSafe disposable flow transducer - the best solution for patients' safety
Screen-type interchangeable disposable pneumotach | ![]() |
Material polyethylene, can be disposed by incineration without toxic emissions | ![]() |
Flow range: -14...+14 l/s | ![]() |
Back pressure: less than 0.06 kPa/(l/s), meets ATS, ACCP & ECCS standards | ![]() |
Accuracy: 3% without calibration, 2% with volume calibration | ![]() |
Sterilisation not required, the entire SpiroSafe flow transducer is disposable | ![]() |
Technical Specifications
Physical dimensions | 107*70*18 mm |
Weight | 305 g |
Frequency response | 0...250 Hz (-3 dB) |
Supply voltage | via USB port |
Temperature correction | Automatic |
Temperature range | +10...+40°C |
Relative humidity range | 5...85% |
Barometric pressure range | 600...1060 hPa |
Quality system | FDA QSR, MDD 93/42/EEC, ISO 13485 |
Safety standards | IEC/EN60601-1, IEC/EN60601-1-2, IEC/EN60601-1-6, IEC/EN60601-1-9 |
Other standards | ISO 26782, IEC/EN 62366 |
System requirements
Operating system | Microsoft Windows Vista, Windows 7, Windows 8 or Windows 8.1 (32 bit and 64 bit) |
Display resolution | 1024x768 (minimum), 1600x1200 recommended with incentive |
CPU | 1 GHz or faster. Dual core, if incentive animation used |
RAM | 1 GB (minimum), 2 GB or more recommended |
CD-drive | Recommended |
USB port | For Medikro spirometer |
Medikro Pro - PC-based Office & Laboratory Spirometer
M915 | Medikro Pro Spirometer with ambient conditions measurement sensors The product consists of the following components:
|
Medikro Pro Spirometer with Consumable Pack
M985 | Medikro Pro Spirometer with Starter Consumable Pack This system includes as starter consumable pack. The system components are:
|
Medikro Pro Spirometer Starter System
M975 | Medikro Pro Spirometer Starter System This system includes all components (excluding the computer and the printer) that the user needs to conduct spirometry tests according to Good Laboratory Practice. The system components are:
|